One by One Auto Changeover Unit

One No. Sump and 2 No. Motors for same Sump to 1 No. OHT or 2 No. Borewells to 1 No. OHT it works.

Soft Touch Button option is provided in the unit 1 By 1 Aco Motor 1 Motor 2 options. If selected 1 By 1 Aco option Among 2No. motors existed in one No. Sump, First 1 Motor gets ON when the water in OHT comes below prefixed level & gets full and OFF. Second time when the water in OHT comes below prefixed level 2nd Motor gets ON & vice versa.

If selected Motor 1 option, only Motor 1 will get ON and OFF, & if selected Motor 2 option Motor 2 only gets ON and OFF.

For 2No. Borewell to 1No. OHT same process as above.

Share

Features
  • Li-Mo-Con switches “OFF” the motor for the following reasons:
    • When the water reaches maximum level in the overhead tank.
    • When there is a low voltage or high voltage.
    • When the water in the sump goes below foot valve.
    • When the water stops flowing to the overhead tank.
    • When the switch is in OFF position.
  • Li-Mo-Con switches the motor ON if:
    • The water in overhead tank falls to prefixed low level i.e., below 75%, 50%, 25% as adjusted.
    • The sump is full irrespective of any levels in the overhead tank except 100%.
    • The switch is in manual position.
    • When the Motor is running and not yet full in OHT, in this stage if current goes and comes later – The Motor will get ON and fill up the OHT even though the water is above ON position in OHT.
Front Facia of Li-Mo-Con
Shows clear indication of water levels in the overhead tank and sump tank.
Shows Voltage variation if any in the left bottom corner, it shows Green indicator for normal voltage, Red indicator for high or low voltage.
Has push to ON/OFF switch to select Auto/Manual operations.
Shows motor ON indication with different colours at different modes of the unit. It shows Green indication in case of Auto mode, Orange indication in case of Manual mode and Red indication while Motor is under dry run condition.
Has soft touch NEED button to switch ON the motor irrespective of any level in the overhead tank.
Has soft touch SILENCE button to mute the audio alarm while motors is under dry run condition.
Shows Green indication upward arrow indication for flowing of water into the overhead tank.
Gives Alarm
When there is voltage fluctuation.
When the motor is under dry run condition due to foot valve blockage or priming fault in Motor.
Demo Options
By pressing the DEMO soft touch button, it shows the Total Functions One by One.
Technical Support
Input voltage:
230/440 Volts AC 50Hz
Power consumption:
2.5 Watts (approx.)
Relay Contact Rating:
One N/O potential free contact rated at 12 Amps at 230 Volts.
Dry Run Time Delay:
150 Sec. in case of priming fault.
Working Voltage:
Motor trips if Volt >250 or <160 AC in case of Single Phase >450 or <350 AC in case of Three Phase.
Power on Delay:
45 Seconds even in Voltage Fluctuations.
Dimensions (mm):
230 x 150 x 63 (LxBxH). Over all Panel Mounting.

Share